Packer water test kit with hoses, gauges and flow meter set up at a borehole

Aardvark Packers supplies the equipment for packer testing: inflatable packers for single-zone and straddle tests, wireline packer systems that test through the drill string, and the water test kits, inflation gear and fittings that tie them together. We have been in business since 1968 and build our packers in Grants Pass, Oregon.

Tell us the hole size, the depth and the test you need to run, and we will help put together tools that work as one system.

Click Here to Contact Us or call 855-546-6488.

What a packer test measures

A packer test seals off one section of a borehole so that water can be pumped into it, or out of it, and the flow measured for that section alone. The results show how permeable the rock or soil is and where water moves through it. The common tests are:

  • Water pressure (Lugeon) tests: water is pumped into the zone at set pressures and the flow is measured. One Lugeon is a flow of 1 litre per minute per metre of test section at 10 bar (about 145 psi).
  • Permeability and slug tests in geotechnical and environmental boreholes.
  • Pump-out (withdrawal) tests: water is pumped out of the zone instead of in.
  • Water tests before grouting: testing each stage before it is grouted shows how open the rock is. The DFI grouting committee’s summary of grouting standards covers how the industry uses them.

What goes into a packer test setup

  • The packers: a single packer tests the hole below it; two packers on one string (a straddle) isolate a zone anywhere in the hole. See Inflatable Packers and Straddle Packers.
  • Inflation: compressed air, nitrogen or water through a regulator and gauge. We recommend 3/16 in nylon inflation tubing rated to 2,500 psi burst, and inflation manifolds when several packers or injection lines run at once.
  • Water supply and measurement: a pump at the surface, and a water test kit with flow meters, hoses, gauges and fittings to read the flow and pressure.
  • For wireline testing: wireline packers, seal tee assemblies and composite cable, described below.

Testing during core drilling: wireline packers

Back in the 1970s, Aardvark worked with Boart Longyear to develop a wireline packer system, and it is still a time saver today. The test runs with the core barrel and bit left in the hole, so there is no need to pull the drill string, which matters most in open or unstable formations.

  • The two-element packer is lowered through the drill string on composite cable, and a bumper seats it in the throat of the bit, which also protects the bit.
  • The casing is then filled with water from a pump at the surface to run the flow test.
  • A seal tee caps the drill string. Its 1 in NPT port takes the injection line, and a compression cap stops pressure loss around the cable.
  • The composite cable combines a high-pressure nylon inflation tube with a steel lifting cable, in continuous lengths up to 2,500 ft (760 m).
  • To test a specific zone, a zone packer can be hung below the wireline packer on perforated tube cut to the zone length, with one inflation line filling both.
  • Wireline packers are available for N, H and P series core barrels, with wireline parts for B, N, H and P, and they can be repaired in the field in minutes.

See Wireline Packers.

Setting the inflation pressure

The packer has to stay sealed against the water standing above it and the pressure you pump into the zone, without going over its rating. For an injection test (pumping in):

G = [(Dp × psi per foot of injection fluid) + Sp + Pp] × 1.1

G is the inflation pressure at the gauge (psi), Dp the depth to the top of the packer (ft), Sp the packer’s unconfined rating for the hole size (psi) and Pp the injection pump pressure (psi). Use 0.43 psi per foot for water and 0.6 for grout. The result must not exceed the packer’s confined rating plus the head between the packer and the static water level.

A worked example: a model 34B packer at 140 ft in a 4 in open hole, with static water at 30 ft and 75 psi of injection pressure, needs about 215 psi at the gauge for a water test. That is inside the 34B’s 325 psi limit in a 4 in hole.

The Inflatable Packer Manual gives the pump-out version, the confined pressure curves give the ratings by hole size, and our inflation pressure calculator does the math.

Running a water pressure test

Your project’s specification sets the pressures, steps and hold times. The packer side of the job runs like this:

  1. Before the first test, check every connection at 25 psi for leaks and make sure the gauge or regulator reads true. Faulty regulators are a leading cause of packer failure.
  2. Note the hole diameter and the static water level, and work out the inflation pressure for the test.
  3. Run the packer or straddle string to depth on drill rods, grout rods or pipe, or lower the wireline packer through the drill string.
  4. Raise the inflation pressure slowly through the regulator until the gauge settles at the calculated pressure.
  5. Pump water into the zone at each pressure step in the specification and record the flow once it steadies.
  6. Release the inflation pressure and give the elements time to relax. Put the end of the inflation line in a cup of water: when the bubbles stop, the packer is deflated and can be moved to the next zone or pulled.

Common questions

Do I need a single packer or a straddle?
A single packer tests everything below it, which suits testing in stages as the hole is drilled. A straddle isolates a zone between two packers anywhere in the hole, so you can test an existing hole zone by zone.

What do I inflate the packers with?
Compressed air, nitrogen or another inert gas, or water. Gas bottles and compressed air are dangerous if misused: follow the bottle instructions, and never test or inflate a packer above ground beyond 25% of its unconfined rating.

Can you supply the whole setup?
We supply the packers, the inflation gear and the water test kit, and we will work directly with you or your engineer so the pieces work together on your hole sizes and depths.

Can test equipment be repaired?
Yes. Our packers are built from modular parts, so glands, seals and O-rings can be replaced in the field, or a packer can come back to us for a rebuild. See Packer Parts.

  • Wireline Packers: permeability testing through the drill string, N, H and P series
  • Inflatable Packers: sliding-head Tigre Tierra® packers for open holes and casing
  • Straddle Packers: two or more packers on one string to isolate a zone
  • Mechanical Packers: surface-set packers with pass-throughs and manifolds for low-pressure injection, sampling and monitoring
  • Water test kits with flow meters, hoses, gauges and fittings
  • Seal tee assemblies in all four sizes
  • Composite cable in continuous lengths up to 2,500 ft
  • Inflation regulators, inflation manifolds and inflation lines rated to 2,500 psi burst
  • Gauge savers and mud balances for grouting work
  • Replacement glands, seals and O-rings for field repair